If your Nest thermostat is connected to a central AC unit, you may have noticed the Compressor Lockout feature in the settings. Can a PEARL adjust the outside damper for different fan speeds? How do I balance a Pelican zoning system? You may freely link What does the zone controller antenna light indicate? Joseph is an HVAC technician and a hobbyist blogger. If your electrician finds that your system is clean and there is no drop in pressure, then it is likely that the system has a faulty low-pressure cutout. Why is Compressor Lockout Important? To me, this seems like a scam to avoid getting service calls that could lead to costly warranty repairs. I asked the installer and they won't do it , he said WA has a rule that mobile homes have to be set at 40* but stick built can be set to 0* if they wanted to be. Right now it's 41F and I am getting 100-103F temps at the vents with the heat pump. I have a heat pump with back up gas furnace. Here are the steps that you will have to do to fix this issue: Dirty filters are one of the main reasons why a compressor lockout happens. Is there a supply air low temperature alarm? The tech did consult the charging chart inside the unit, and I believe it was within a couple of PSI. Compressor Lockout - Recovery - HVAC-Talk: Heating, Air & Refrigeration Set Compressor Lockout to the temperature below which it is inefficient to run the heat pump. How do I adjust how long a thermostat keeps the fan enabled after a heating or cooling cycle? Will My Generator Work After an Emp? Scan this QR code to download the app now. Setting 0350 is described as the "Heat Pump Compressor Lockout (Balance point)." The available settings are no compressor lockout and 15-45 degrees F in 5 degree increments. When a compressor locks out, it means that the compressor has shut down due to an overload or excessive heat. "The tech did consult the charging chart inside the unit, and I believe it was within a couple of PSI. This is an old method of cooling systems. In this blog post, well explain everything you need to know about compressor lockout and how it can benefit you. To prevent any damage, a cutout mechanism helps avoid any unwanted damage to the appliances compressor. Is there a purge cycle at the end of a heating or cooling cycle? I have a Lennox EC10Q3-20 furnace about 20yrs old and there's a separate air conditioning unit on the outside of the house. How do I rename an existing shared schedule? How Do I Turn on The Auxiliary Heat on My Nest Thermostat? It causes the compressor to shut down automatically. Honeywell PRESTIGE THX9321 - Manual (Page 35) Do I have Pelican economizer controllers? But you are right about your heat pump. As for calculating costs, the gas company uses a fairly simple formula so it's pretty easy to calculate the total cost per therm used (about $1.44 at the moment). How do I schedules with occupancy sensors? Can a Z8 or Z24 control a separate supply and return damper actuator? When it gets below 40F, it loses efficiency. Sounds like it has been set up to control a fossil fuel aux heat. Let you investigate if some popular compressors have this feature or not: Yes, York fs1 can compressor lockout. How do I stop an email from receiving notifications? I assume that the lower the setting, the more often the unit must defrost. It can be caused by dirty condenser coils as well. Joseph loves to talk about HVAC devices, their uses, maintenance, installation, fixing, and different problems people face with their HVAC devices. What does the Outside Ventilation setting do? Balance point setting for dual fuel : r/HVAC - Reddit If you live in an area with cold winters, its a good idea to have a backup heating source for your home. What are the remote temperature readings? Now that you know what nest compressor lockout is, we hope youll be able to heat your home more comfortably while at the same time being careful on saving some energy costs. How does Pelican calculate Usage Graphs runtime, cost and energy? What is an economizer low limited mixed air temperature? My infrared thermometer temps at the vents are 102-103F with an ambient outdoor temp in the low 40's. However, just a few days ago, the temperature was down in the single digits. Yes. about energy and home comfort issues (specific to HVAC systems). Nest thermostats can also be used to control other devices in your home, such as your lights and security system. This will prevent your AC unit from turning on and trying to cool your home when the outside temperature is too cold. "My balance point seems to be around 20 degrees, so I guess my real questions is, am I putting undo stress or damaging the compressor by having the lockout set below 40 degrees like the tech said, or is having it set to 25 or even 20 degrees fine?". Although there are various lockouts, you have to enable the compressor by pressing the reset button in the compressor. Can I schedule when notifications are active? W -> W 5. A forum community dedicated to Do it yourself-ers and home improvement enthusiasts. Let's start with the capacity. You will need to send a request to Pelican Technical Support to add this configuration to your thermostats. When the system was installed the technician set the lockout temperature to 40 degrees. Can I disable or lock the thermostats Fan Button? Trane rep agreed with this setting. I'm assuming that I use the configuration on page 36 "4 Wire Heat/Cool System" and use the following mapping So that, when outdoor temperatures fall below 30 degrees, the auxiliary heat will kick into action. I would like it to use only gas furnace when its below 30 outside. As a homeowner, you may not think about your air conditioner very often. He created Hvacbuster to share his knowledge and decade of experiences with people who dont have any prior knowledge about these devices. suggestions. Thank you. I am new to a heat pump. My visionpro T-stat does everything I need other then tell which stage of aux. Accessories Pumps, Cooling Towers, Evap Condensers, etc, Components Valves, Motors, Condensers, Evaporators, etc, Duct Systems Design, Installation & Practice, Piping Systems Design, Installation & Practice, Control System Design, Installation & Practice, Pro's Forum: National Electrical Code (NEC), Pro's Forum: Calculations & Electrical Theory, Pro's Forum: Electrical Business & Marketing. There's also the matter of the outside temperature your Ecobee uses not . Does a Pelican gateway use a DHCP or static IP address? Since it would need to operate at a COP of 3.6 just to break even with a 90% efficient gas furnace. G (enter 44550) [url]http://www.hunterfanhq.com/hiw-prod/orderinv/frames/ps_frame.htm[/url] When will an Economizer position failure notification be generated? To prevent your Pelican thermostat from turning on your Heat Pumps compressor(s) when it is extremely cold outside, you can use Compressor Lockout. This is usually caused by a pressure imbalance in the system, which can be caused by a variety of factors. Lockout mode on a compressor means that it will not work until the user has manually reset it. When the compressor gets clogged up or the air filters of the compressor get dirty, it causes the compressor to cause problems. Therefore, to start the appliance after a compressor lockout, you will have to press the compressor reset button manually. Is this normal. There is an underlying issue that caused the trip. A dirty compressor can cause a high-pressure lockout. And during a southwest Illinois cooling season, that temperature range can mean that youll rack up some significantly larger heating bills. to this site, and use it for non-commercial use subject to our terms of use. What does a PEARLs Variable Speed Fan (VFD) configuration do? My parents had a Nest and ended up switching back to their old thermostat. How do I commission to economizer requirements? How to I check if a zone controller is having wireless communication issues? How do I schedule events for multiple rooms? I just want to double check on the wiring before I connect everything. There are various brands and types of compressors available in the market. How do I set an individual room schedule? T8195B -> 44550 As the outdoor temperature drops, the capacity of the heat pump drops because there's less heat to extract and pump indoors. You will need to send a request to Pelican Technical Support to add this configuration to . There is a compressor reset button in the outdoor unit of an air conditioner. As a result, the compressor tries to minimize or prevent any damage by turning off by high-pressure lockout. (Quick Answers), Samsung Dishwasher Soap Dispenser Not Opening? But for it to be effective at doing that, there needs to be enough heat energy available and as the temperature drops outside, not only does your home take more energy to keep warm, theres less heat energy that your heat pump can extract from the outside air. What do the symbols on a Pelican thermostats display mean? See next question. A reset means something tripped. High-pressure lockout is mainly caused due to the lack of air around the indoor unit. That is when your emergency heat will kick in to supplement your heat pumps heating. is running but it does indicate that an auxiliary stage is on. To understand why this is a bad thing, you have to know a little about heating efficiency. Balance Point (Compressor Lockout) Off, 5 F to 60 F (in 5 F increments) or -15.0 C to 15.5 C (in 2.5 C or 3.0 C increments) Compressor Lockout requires an outdoor temperature. The HeatPump Aux lockout (setting 360) set to 40 degrees F, or 4.5C. (Explained). If the condenser coils inside the system get dirty due to the dust of the outside environment, then it may cause the system to overheat. If your heat pump can keep your home warm down to, say, 30 degrees F, but your balance point is set to switch over to backup heat at 40 degrees, then anytime the temperature is in the 30- to 40-degree range, youll be paying too much for heat (if you use electric backup heating). Yes, Nest can compressor lockout. If the compressor loses power, it will shut down to prevent damage to the system. If the electrician charges the system with more than 450 500 PSI of refrigerant, the high-pressure cutout may trip. The purpose of the lockout relay is to keep the compressor off when there is a significant fault, EVEN if the fault condition goes back to normal. Compressor lockout is an essential safety feature for compressors. Here is the manual for the Hunter 44550. The C.O.P. What are Parallel Fan Powered Variable Air Volume (PFB-VAV) systems? I run my heat pump all the time at these temps (I have to as the heat pump is my primary source of heat). Piero Fusco. Lockout can be interpreted in more than one way. Y -> Y/Y1 Honeywell T6 Pro Z-Wave Thermostat - Installation Manual I don't want to pay a fortune for a Tstat with lights when this one does everything I need other than have a few indicators. problems contact webmaster@doityourself.com. It would be nice to have an indicator that I could turn on or off if I got tired of the lights off the wall bracket. That is in regions where the temperature doesnt fall below 30 degrees. var q1ezhd9u1df5n34; (function(d, t) { var s = d.createElement(t), options = { 'userName':'cornerstonead', 'formHash':'q1ezhd9u1df5n34', 'autoResize':true, 'height':'662', 'async':true, 'host':'wufoo.com', 'header':'hide', 'defaultValues':'Field6=' + encodeURIComponent(encodeURIComponent(typeof wca == "undefined" ? "" When the temperature outside is too cold, the compressor has to work harder to cool the refrigerant, which can cause it to overheat and break down. As a result, the indoor unit will not get enough air in the system. It provides multiple flashes on the control panel when get signal from a compressor lockout. How do I make a copy of a shared schedule? The heat pumps economical balance point would be around 50F. Note that passwords are case-sensitive. This can help prolong the life of your compressor and save you money on your energy bill. Can I set a time delay before a PM5 turns off with On-Demand Start? Can I set utility electrical and gas costs into Pelican? What is the difference between 0% versus Disabled weighted remote sensor averaging? This feature is designed to protect your AC unit from damage by turning it off when the outside temperature is too cold. I don't know it this had anything to do with it, but the outside temperature yesterday (during service call) was about 65 - 70. To learn more about heat pumps, energy savings and efficiency ratings such as COP and the Heating Seasonal Performance Factor (HSPF, which looks at efficiency over an entire heating season), contact Ernst Heating and Cooling. How does the PEARL calculate where to place the outside damper during an economizer cycle? The lockout function can be set to different temperatures, depending on the climate and the type of compressor. Can I schedule the thermostat to set its heat setpoint beyond the heat range? The compressor will not turn on until you do not press the reset button. What is the Maximum Ventilation Position? Your heat pump is designed to run at low ambient temps (long run times). Components Coils, Heaters, Motors, etc. Therefore, clean the fan and check if it is running or not. If emergency heat is already activated, select leave on to leave it on or turn off to deactivate it. As for why the heat pump stopped working in the first place, he wasn't sure, but a lower pressure lockout is something usually associated with cooling, not heating. Additionally,airlucent.comparticipates in various other affiliate programs, and we sometimes get a commission through purchases made through our links. This may be due to the age of the system. Compressors lock-out is available on different thermostats and systems but usually, it wont be explicitly displayed. How to reset compressor lockout? The government states that the control for lockout temperature shall be at maximum 40 degrees and 32 degrees or less at final inspection. Can I set a Pelican gateway for a static IP address? I have a forced air system. Does your system use 410A refrigerant or R22 refrigerant? It's about convenience and not having to worry about snow on the heat pump. Another common cause of a compressor lockout is a loss of power to the compressor. When the outside temperature is too cold, the Compressor Lockout feature will turn off your AC unit. When you get down close to freezing or below the blue flame is the way to go. I have a horribly set up duct system with a tempstar 13 seer and have had no problems with even a 15 degree cutout temp. VerticalScope Inc. All Rights Reserved. Heat pump - how to determine compressor lockout (aux heat only - Reddit 2. The lock-out temp should be at the economic balance point of the home. The compressor lockout is a feature that is built into most AC units. Not part of the original programming but a temporary setting until I fixed my inducer motor on the furnace. A compressor lockout is simply the temperature below which you want to use auxiliary heating (emergency heat) rather than your heat pump compressor. When programming the thermostat, the electrician set it as if I had a Multi-Stage Heat Pump. Save my name, email, and website in this browser for the next time I comment. The Compressor Lockout feature is a safety feature that is designed to protect your AC unit from damage. are (remember, as long as Aux Heat isn't on)? A Simple Way to Calculate Heat Pump Balance Point Balance point can be no greater than 30F. 1y. Does Pelican track any critical or private information or data. What are the different schedule Repeat options? How do I get to a room climate control page? What are Series Fan Powered Variable Air Volume (SFB-VAV) systems? Best temp lockout Balance Point? - DoItYourself.com How do I choose which days my site is on vacation? I changed this to 15 degrees. . I have a 5 month old Rheem Heat Pump with gas backup and I have a question about the compressor lockout temperature setting. Two Ways to Change the Heat Pump Balance Point C -> Not connected Can I set a mixed air low limit for a PEARL? This is where I think it was improperly programmed or even wired improperly. For example, if you are using a Nest thermostat for your HVAC system, you wont be able to explicitly see anything like lockout. However, youll see something like Use the heat pump compressor when the outdoor temperature is above. Website operating I have switched it back and forth between 15 and 20 and think 15 works better here. Houzz Pro: One simple solution for contractors and design pros, New project for a new year: Swap your conventional heater for an energy-saving model and dont be fooled by misinformation, Keep dollars in your pocket and preserve a precious resource with these easy DIY strategies, Landscape Architects & Landscape Designers, Outdoor Lighting & Audio/Visual Specialists, Fort Collins Home Automation & Home Media, Glendale Heights Home Automation & Home Media, Safety Harbor Home Automation & Home Media, Windsor Locks Home Automation & Home Media. Due to the non-condensable in the system, it will cause a high-pressure lockout. What zone controller do my thermostats communicate with? High-pressure lockout is caused due to the indoor unit or the compressor not getting sufficient air around it to operate properly. Compressors are an essential part of various electrical appliances. THey are: Option 08 - Auxiliary Heat Lockout Temperature Option 09 - Heat Pump Lockout Temperature Either of these can be set to Off, or from 5-55F in 5 degree increments. Or is it dependent on how far apart the actual and desired temps. Compressor lockout mainly happens when the appliance is working hard. The compressor is the part of your HVAC system that pressurizes refrigerant and circulates it through the coils. Compressor lockout is an essential safety feature. Recommendations? A compressor lockout is a device that is used to prevent the compressor from running when there is no demand for cooling. How do I add an email for receiving notifications? Questions About Becoming A Professional Member? It is necessary to press the button after a lockout occurs. When a compressor turns on lockout mode, you have to turn it on again by pressing the reset button manually. The thermostat shall have a compressor outdoor lockout and backup heat outdoor lockout to turn off the heat pump or backup heat based on outdoor temperature. What should I set a thermostats Reversing Valve too? Yes, you can unlock a compressor. When is a low battery notification generated? JavaScript is disabled. Please enter a valid email address for yourself. How do I schedule an event for a single room? However, the aux heating cost be 2-5 times more than heat pumps. How to force HP below balance pont (Honeywell VisionPRO) Here's the long story: I was told that the balance point was set to 30 degrees F. That's fine, I want to use as little propane as possible. I currently have Heat Pump Compressor Lockout (setting 350) set to 20 degrees F, or -9.5C. Our goal is to help educate our customers in Hamel, Alton, Glen Carbon, Highland, Greenville, and Troy, Illinois and surrounding areas about energy and home comfort issues (specific to HVAC systems). This way, you wont have to go without heat if your heat pump goes into lockout mode. I just hate to have it cycling between one and two stages of strips if I can keep from it. But this essential component may face some issues while using. Yes. It was below 30 degrees when they installed them so not warm enough to run on heat pump. Can I hide or make a thermostat disappear? What am I suppose to set the Backup heat lockout to? : r/HVAC - Reddit I have my heat pump (compressor) lockout set for 40F. I've changed this setting myself several times and it's currently set to 25 degrees. There may be a mechanical outdoor air stat in the heat pump if the wall control isn't doing it. I could see the gauges but was too far away to read the chart myself. For the record, I current have it set to 15. When will a cool failure notification be generated? Can a PEARL control a separate supply and return damper actuator? hbbd```b``n@$=w.)Hq:,R"xH|i(6_, b30E"! A heat pump works as an air conditioner in the cooling season and as a heater in the heating season. The Honeywell only does 5 degree increments. What was actually reset? What voltage floating actuators can a Pelican thermostat control? As a result, it will cause a high-pressure lockout. In appliances, a compressor may get overheated or jammed. No matter which setting you choose, Heat Pump Balance determines how often . (Fixed), Whirlpool Dishwasher Buttons Not Working? Please enter the name by which you would like to log-in and be known on this site. Heat pumps are equipped with a reverse valve that switches the direction of the refrigerant, enabling the heat pump to work as a heater in one position and an air conditioner in the other. When the outdoor temperature falls below this limit, the heat pump will shut off to prevent damage. The tech said it was a L21 (Lockout - Low Pressure Control Trip). Could be 15, 20, 24 degrees F etc. A subreddit for Heating, Ventilation, & Air Conditioning Technicians. Heres everything you need to know about the Compressor Lockout feature and how it can help you save money and keep your AC unit safe. Point requires an outdoor sensor. How do I make a delete a shared schedule? What temperature should I set compressor lockout? Provide the pricing and I'll work the numbers for you. W Heat pump w/electricity at 12 cents per kw-hr, Coefficient of Performance = 3 at 35F ambient:(1,000,000 / 3414 btu per kw-hr) x .12 / 3= $11.71. Were proud to serve homeowners in Hamel, Edwardsville, Troy and other southwest Illinois communities. (Read This First! I'm not sure if it's more cost effective to run the heat pump, strips, or both depending on temp Around here we tell people to set it or just go on over to AUX when its down to around 20oF. Dirty compressors are the main reason behind compressor overheating. honewell t6 pro and heat pump. - HVAC-Talk: Heating, Air Can I schedule when Fan Circulation Minutes is active? This prevents any damage to the compressor and prevents anything worse from happening. What is on a rooms climate control page? It is harder to charge when it is cold outside, but can be done. How do I add a new gateway to my existing site? How do I add a new user to my Pelican site (web-app)? Maybe I need some education here, but as long as Aux Heat [B]doesn't[/B] come on, wouldn't the heated air coming out of the vents always be more or less the same temperature until the area achieves the desired temp. 1. This will cause the system to overheat its compressor which causes a low-pressure cutout. Blank (default): If left Blank then the thermostat will not use outside Compressor Lockout. Participate in over 40 different forums and search/browse from nearly 3 million posts. Maybe the Honeywell Prestige or Ecobee? Presuming you use 290 KWHs a month on without using any heat. For example, right now it's 33 outside according to the outdoor sensor and it's using the gas furnace. I had to use the heat pump exclusively until I completed the necessary repair. When would I disable the thermostats internal sensor? Option 2: (Balance point/Aux Heat +2F droop): Compressor works only above auxiliary lockout temperature, backup heat works only below balance point, 2F droop between temperatures. If I leave it set to 25 degrees then I suspect I'll be charged for all service calls and maybe even any future repair costs. This is when your home HVAC system switches over to backup heat, usually an electric resistance heating element. What is the economizer sequence of operation? Its not going to prevent setting by outdoor temperatures. How to fix a compressor lockout? When it hits the lockout temperature, it starts using the auxiliary heat on the system based on the lockout temperature is set on the system. Why is the relay wiring module not communicating? If you dont know whether your heating system has aux heat, you can verify this by: However, if you are sure that your system has secondary heating, but aux heat is not working, then your thermostat wires could be loose or not connected properly.